CALIBRATOR
The Fluke 9143 Field Metrology Well extends high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance. It is packed with functionality and are remarkably easy to use. Moreover it is lightweight, small, and quick to reach temperature set points, yet it is stable, uniform, and accurate. This industrial temperature loop calibrator is perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field.
Key Features & Specifications
- Lightweight, portable, and fast
- Temperature range: 33°C to 350°C
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.02°C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Base Unit Specifications
Temperature range at 23°C –25°C to 150°C (–13°F to 302°F)
Display accuracy ±0.2°C full range
Stability ±0.01°C full range
Axial uniformity at 40 mm (1.6 in) ±0.05°C full range
Radial uniformity ±0.01°C full range
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) ±0.006°C full range
Hysteresis 0.025
Operating conditions 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental conditions (for all specifications except temperature range) 13°C to 33°C
Immersion (well) Depth 150 mm (5.9 in)
Insert OD 30 mm (1.18 in)
Heating time 16 min: 23°C to 140°C
23 min: 23°C to 150°C
25 min: –25°C to 150°C
Cooling time 15 min: 23°C to –25°C
25 min: 150°C to –23°C
Resolution 0.01°
Display LCD, °C or °F user-selectable
Size (H x W x D) 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight 8.16 kg (18 lb)
Power requirements 100 V to 115 V (±10%) 50/60 Hz, 635 W 230 V (±10%) 50/60 Hz, 575 W
Computer interface RS-232 and 9930 Interface-it control software included
-P Specifications
Built-in reference thermometer readout accuracy (4-Wire Reference Probe)1 ±0.010°C at -25°C
±0.015°C at 0°C
±0.020°C at 50°C
±0.025°C at 150°C
±0.030°C at 200°C
±0.040°C at 350°C
±0.050°C at 420°C
±0.070°C at 660°C
Reference resistance range 0 ohms to 400 ohms
Reference resistance accuracy2 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizations ITS-90, CVD, IEC-751, Resistance
Reference measurement capability 4-wire
Reference probe connection 6-pin Din with Infocon Technology
Built-in RTD thermometer readout accuracy NI-120: ±0.015°C at 0°C
PT-100 (385): ±0.02°C at 0°C
PT-100 (3926): ±0.02°C at 0°C
PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range 0 ohms to 400 ohms
RTD resistance accuracy2 0 ohms to 25 ohms: ±0.002 ohms
25 ohms to 400 ohms: ±80 ppm of reading
RTD characterizations PT-100 (385),(JIS),(3926), NI-120, Resistance
RTD measurement capability 4-wire RTD (2-,3-wire RTD w/ Jumpers only)
RTD connection 4 terminal input
Built-in TC thermometer readout accuracy Type J: ±0.7°C at 660°C
Type K: ±0.8°C at 660°C
Type T: ±0.8°C at 400°C
Type E: ±0.7°C at 660°C
Type R: ±1.4°C at 660°C
Type S: ±1.5°C at 660°C
Type M: ±1.4°C at 660°C
Type L: ±0.7°C at 660°C
Type U: ±0.75°C at 600°C
Type N: ±0.9°C at 660°C
Type C: ±1.1°C at 660°C
TC millivolt range –10 mV to 75 mV
Voltage accuracy 0.025% of reading + 0.01 mV
Internal cold junction compensation accuracy ±0.35°C (ambient of 13°C to 33°C)
TC connection Small connectors
Built-in mA readout accuracy 0.02% of reading + 2 mV
mA range Cal 4-22 mA, Spec 4-24 mA
mA connection 2 terminal input
Loop power function 24 V DC loop power
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C) ±0.005% of range per °C