Sumatera Utara - Medan

HANNA HI88703 Bench Laboratory Turbidity Meter

Harga :
CALL
Lokasi :
Sumatera Utara - Medan
Dilihat :
2 Kali
Update Terakhir :
17-11-2019 17:22

Dapatkan Spesifikasi Harga HANNA HI88703 Bench Laboratory Turbidity Meter Produk Terbaik dari CV. Gihon Juma Sentosa Jual Alat alat laboratorium berupa: Microbiology, Chemical and Reagent, Laboratory and Scientific Equipment, Medical Equipment, dan Glassware

Detail Produk

TURBIDITY METER The HI 88703 turbidity benchtop meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges. This instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected. A two, three, four or five-point calibration could be performed by using the supplied standards. When user prepared standards are used, calibration points can be modified. H 88703 features complete GLP ( Good Laboratory Practice) functions that allows traceability of the calibration conditions. The last calibration points, time and date can be checked. Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software. Features:  Two measuring ranges: Ratio turbidity, non-ratio turbidity Meets USEPA requirements GLP features Two, three, four or five point turbidity calibration USB PC connectivity Log up to 200 measurements Contextual help and tutorial mode Specification: Range    Non Ratio Mode    0.00 to 9.99; 10.0 to 40.0 NTU; 0.0 to 99.9; 100 to 268 Nephelos 0.00 to 9.80 EBC Ratio Mode    0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.0 to 99.9; 100 to 26800 Nephelos 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC Resolution    Non Ratio Mode    0.01; 0.1 NTU 0.1; 1 Nephelos; 0.01 EBC Ratio Mode    0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC Range Selection         automatic Accuracy @25°C         ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC) ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC) Repeatability         ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC)whichever is greater Stray Light         < 0.02 NTU (0.15 Nephelos; 0.01 EBC) Light Detector         silicon photocell Method         Nephelometric method (90°) or Ratio Nephelometric Method(90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B. Measuring Mode         normal, average, continuous Turbidity Standards         <0.1, 15, 100, 750 and 2000 NTU Calibration         two, three, four or five-point calibration Light Source/Life         tungsten filament lamp / greater than 100,000 readings Display         40 x 70 mm graphic LCD (64 x 128 pixels) with backlight Log Memory         200 records PC Interface         USB Environment         0°C (32°F) to 50°C (122°F); max 95% RH non-condensing Power Supply         230 V/50 Hz or 115 V/60 Hz 20 W; auto-off after 15 minutes of non-use Dimensions         230 x 200 x 145 mm (9 x 7.9 x 5.7”) Weight         2.5 Kg (88 oz.) Includes: HI 88703-02 ( 230V) is supplied with sample cuvettes and caps ( 5) , calibration cuvettes, silicone oil ( HI 93703-58) , tissue for wiping cuvettes, power cord and instruction manual.

Permintaan Penawaran

Link