Dapatkan Spesifikasi Harga HANNA HI88713 Bench Laboratory Turbidity Meter Produk Terbaik dari CV. Gihon Juma Sentosa Jual Alat alat laboratorium berupa: Microbiology, Chemical and Reagent, Laboratory and Scientific Equipment, Medical Equipment, dan Glassware

Detail Produk

TURBIDITY METER The HI 88713 turbidity bench meter meets and exceeds the requirements of the  ISO 7027 standard. HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected. A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used. The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process. Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software. Specification: Range    FNU Mode    0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU FAU Mode    10.0 to 99.9; 100 to 4000 FAU NTU Ratio Mode    0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC NTU Non-Ratio Mode    0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC Resolution    FNU Mode    0.01; 0.1; 1 FNU FAU Mode    0.1; 1 FAU NTU Ratio Mode    0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC NTU Non-Ratio Mode    0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC Accuracy @25°C    FNU Mode    ±2% of reading plus stray light FAU Mode    ±10% of reading NTU Ratio Mode    ±2% of reading plus stray light / ±5% of reading above 1000 NTU NTU Non-Ratio Mode    ±2% of reading plus stray light Range Selection         automatic Repeatability         ±1% of reading or stray light, whichever is greater Stray Light         < 0.1 NTU (0.05 EBC) Light Detector         silicon photocell Light Source         IR LED Method         ISO 7027 Method Measuring Mode         normal, average, continuous. Turbidity Standards         <0.1, 15, 100, 750 FNU and 2000 NTU Calibration         two, three, four or five-point calibration Log Memory         200 records PC Connectivity         USB Environment         0°C (32°F) to 50°C (122°F); max 95% RH non-condensing Power Supply         12 Vdc power input Dimensions / Weight         230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.)

Permintaan Penawaran

Link