WEATHER STATION
The Lufft family of multi-parameter weather sensors offer a cost-effective, compact alternative for the acquisition of a variety of measurement parameters on land- and buoy-based weather stations. Depending on the model, each sensor will measure a different combination of weather parameters to meet a wide variety of applications.
Air Temperature & Humidity
Temperature is measured using a highly accurate NTC-resistor, while humidity is measured using a capacitive humidity sensor. Both sensors are located in a ventilated radiation shield to reduce the effects of solar radiation.
Pressure
Absolute air pressure is measured using a built-in MEMS sensor. The relative air pressure referenced to sea level is calculated using the barometric formula with the aid of the local altitude, which is user-configurable on the equipment.
Wind Speed & Direction
The wind sensor uses four ultrasound sensors which take cyclical measurements in all directions. The resulting wind speed and direction are calculated from the measured run-time sound differential.
Compass
The integrated electronic compass can be used to check the north-south adjustment of the sensor housing for wind direction measurement. It is also used to calculate the compass-corrected wind direction.
Precipitation
Tried and tested radar technology is used to measure precipitation. The precipitation sensor works with a 24GHz Doppler radar, which measures the drop speed and calculates precipitation quantity and type by correlating drop size and speed.
Features :
All in One
Aspirated temperature/humidity measurement
Maintenance-free operation
Open communication protocol
UMB-ASCII
UMB-Binary
SDI-12
MODBUS
Analog outputs in combination with 8160.UDAC.
Includes :
WS600 Multi-Parameter Weather Sensor
10m sensor cable
Operations manual.
Specifications :
Air Temperature
Principle: NTC
Measuring Range: -50 to +60 C
Resolution: 0.1 C (-20 to +50 C); otherwise 0.2 C
Accuracy: +/-0.2 C (-20 to +50 C); otherwise +/-0.5 C
Units: C; F.
Humidity
Principle: Capacitive
Measuring Range: 0 to 100% RH
Resolution: 0.1% RH
Accuracy: +/-2% RH
Units: % RH; g/m3; g/kg.
Pressure
Principle: Capacitive
Measuring Range: 300 to 1200hPa
Resolution: 0.1hPa
Accuracy: +/-1.5hPa
Unit: hPa.
Wind Speed
Principle: Ultrasonic
Measuring Range: 0 to 60m/s
Resolution: 0.1m/s
Accuracy: +/-0.3m/s or 3% (0 to 35m/s); +/-5% (>35m/s)
Response Threshold: 0.3m/s
Units: m/s; km/h; mph; kts.
Wind Direction
Principle: Ultrasonic
Measuring Range: 0 to 359.9 degrees
Resolution: 0.1 degrees
Accuracy: +/-3 degrees
Response Threshold: 0.3m/s
Compass
Principle: Integrated Electronic Compass
Measuring Range: 0 to 359.9 degrees
Resolution: 1.0 degree.
Precipitation
Principle: Radar
Measuring Range: 0.3mm to 5.0mm
Liquid Precipitation Resolution: 0.01mm
Precipitation Types: Rain, Snow
Repeatability: Typically> 90%
Response Threshold: 0.01mm.
Technical Data
Interface: SDI-12, Modbus
Operating Temperature: -50 to +60 C
Operating Humidity: 0 to 100% RH
Included Cable Length: 10m.