Detail Produk

CALIBRATOR OMEGA’s new hot point® calibrators allow calibration of thermocouple and RTD probes quickly and easily with accuracy to 0.9°C (1.5°F). An integral RTD sensor assures high measurement accuracy and repeatability. A built-in microprocessor-based PID digital controller assures exceptional stability. Setpoint and actual temperature are displayed simultaneously. Temperature can be set in one-degree increments from 22°C (40°F) above ambient to 482°C (900°F).  The CL900 calibrator accepts a variety of standard and metric optional inserts which are available in 4" and 6" depths and for probe diameters from 1/8" to 3/8". An undrilled insert is also available. The CL900 comes complete with a 1/4" diameter, 6" deep insert well and insert block tongs. Additional inserts can be ordered separately as required for other diameter probes. 6" depth inserts are used for probes 7" and longer; 4" depth inserts are used for probes 5" and longer. The CL950 calibrator features a built-in well with 5 ports sized to accommodate a 1/16", 1/8", 3/16", and two 1/4" diameter probes. The multi-port design allows for the use of a calibrated or NIST-traceable probe and meter to be used as a standard while calibrating other probes. The 5 port design also allows for calibration of more than one probe at a time, and eliminates the need for separate insert wells. Specifications (All specifications are based on the test probes being in contact with the bottom of the test well) Temperature Range: Ambient +22 to 482°C (+40 to 900°F) Operating Ambient Temperature Range: 5°C to 38°C (40°F to 100°F) Accuracy: (1°F resolution) CL900 with 6" test well inserts: ±1.5°F ±1 LSD. CL900 with 4" test well inserts: ±3°F ±1 LSD. CL950: ±1.5°F, ±1 LSD. Control Stability: ±0.3°F or better Temperature Uniformity (within the bottom 1" of the test well): CL900: with 6" test well inserts: 0.3% with 4" test well inserts: ±0.4%. CL950: ±0.3% Max. Probe Immersion: CL900: with 6" test well inserts: 150 mm (6") with 4" test well inserts: 100 mm (4"). CL950: 150 mm (6") Control: Microprocessor-based PID digital controller with data retention Power: 110-125 Vac, 50/60 Hz, 1050 watts; 220 Vac, 50/60 Hz, 1050 watts Dimensions: 300 H x 216 W x 311 mm D (11.75 x 8.5 x 12.25") Weight: 10.1 kg (22.3 lb)

Permintaan Penawaran

Link